DEMO EXISTING SFR, NEW 2-STORY SFR, 4BED/3BA, 553 SF ATTACHED GARAGE, 82 SF COV'D FRONT PORCH, 70 SF COV'D REAR PATIO, 70 SF COV'D REAR DECK (LUA2025-0074) REVISION 1 (11.17.25, APPRVD 12.3.25): TO MODIFY ENERGY CODE METHOD FROM PRESCRIPTIVE TO U-FACTOR COMPLIANCE PATH. PROPOSED R-10 FULL SLAB INSULATION REPLACES CONTINUOUS INSULATION ON EXTERIOR. REVISED SHEETS A1.0 AND A5.1. ALTERNATIVE METHOD & MATERIAL (12.19.25, APPVD 12.23.25) -AIR ADMITTANCE VALVE (AAV/STUDOR VENT) FOR THE KITCHEN SINK DUE TO THE CORNER WINDOWS IN FRONT OF THE SINK AND A 4-STUD POST WITH HOLD DOWN THAT CAN NOT BE PENETRATED ADJACENT TO THE SINK. DUE TO THE TIGHT CORNER CAINET CONDITION, FURRING OUT THE SINK CABINET IS NOT A VIABLE OPTION AS IT WOULD AFFECT THE ALREADY TIGHT KITCHEN WALKING PATH.
Submitted May 16, 2025Issued Aug 1, 2025Finaled Jun 18, 2026
Permit data from the City of Lake Stevens Citizens Connect permit portal