24 120002 TJClosedAPP COMPLETE AUG 28, 2024 · ISSUED AUG 30, 2024 · COMPLETED APR 08, 2025
EXT 3/20/25 MD
Underground horizontal directional boring using surface launched drill to install 2" Comcast conduit to 4774. Starting at Comcast ped located near NW corner of 4762's property, crew will bore W/S approx 64' to a placed carson and S/SW approx 51' to a placed carson on S side of driveway. Route will finish on private property E approx 52' to 4774's connection. Potholing for water and sewer lines is needed. 1' of vertical clearance will be kept from utility lines. 5' of horizontal clearance will be kept from water
and storm mains. Max pothole dimension 2' x 2'.