New construction R-3 townhomes, VB construction, 4 - 1,690 sqft units 3-bedroom,3-bathroom, 3 floors w/garages (Related SDEV25-0208) Mechanical and plumbing scope included ***FRR26-0118 APPROVED: Revision to Energy Forms*** ***Field Revisions # 2 FRR26-0123. Approved 7.17.26_ We have provided a revised detail along with the associated code language that allows both layers of sheetrock be applied to the same side of wall stud as has been installed onsite. Note that two layers of 5/8 type X applied to the same side of each firewall face also creates a 2-hour fire rated wall by code, although only a 1 hour rated wall is actually required if the building also has a fire suppression system. The subject building has full fire suppression. Also, please note that this same fire wall configuration was recently approved on another project in the city of Tacoma located at 6618 52nd Ave W.